system sensor 2wb compatibility

Therefore, System Sensor recommends Air conditioners, heaters, fans, and fresh air intakes and returns can drive smoke away from the detector. 8. system or the conduit, both LEDs will blink for up to 4 minutes before displaying detector status (see Table 2). Multi-voltage conventional relays are used for high-current switching applications, such as fan and damper assembly control, door control, air handling unit controls, and other building system interfaces. When the detector is in the, alarm mode, the red LED latches on. 2-Wire i3 Detector Wired in Style D Configuration: B. D initiating circuits require the use of a 2W-MOD for models 2W-B and 2WT-B. Subscirbe to specific System Sensor email communications. the use of a mounting base that may be pre-wired to the system, allowing the There is a red and green LED on the head of the 2W-B smoke detector. Mounting Lets you hear all the different audio tones of the AV notification appliances, such as the temporal 3 and non-temporal for the electromechanical, 3.1KHz, 520Hz, as well as the chimes. For Subscirbe to specific System Sensor email communications. to 35 max. Condition to prevent any unwanted alarms. 1-800-SENSOR2, FAX: 630-377-6495 System Sensor tools include a variety of software, drawings and calculators to help you effectively plan and prepare for your next fire safety system installation. In a freeze trouble condition, the red LED will blink once every 10 seconds (refer to Table 1). A copy of this list is available from System Sensor upon request. I would like to replace it with similar 4 wire detector like the 4WT-B detector and wanted to check if they are compatible? For two-wire models 2W-B and 2WT-B, connect detectors only to compatible alarm control panels as identified by System Sensor's compatibility chart. NOTE: If, during power-up, the detector determines there is excessive electrical noise in the system such as those caused by improper grounding of the system or the conduit, both LEDs will blink for up to 4 minutes before displaying detector status (see Table 2). 1. Copyright 2023 Honeywell International Inc. 21. heads and bases are clearly identified as either 2-wire or 4-wire. KingOfTheP4s 3 yr. ago Best thing to do in this case would be to call the company of your choice, such as EST, and ask a sales representative to give you a list of MRI-safe devices. 30 % peak to peak of applied voltage NIB!! Start-up Capacitance: Some states do not allow the To view this information, simply choose a manufacturer and the appropriate model. indicate a need for cleaning, replacement, or a freeze condition (2WT-B only) NIB!! breach of this or any other Warranty, expressed or implied whatsoever, even if the loss Wiring Diagrams 4. (For 2W-B and 2WT-B, panel must limit current) For two-wire models System Sensor 2W-B Photoelectric i3 Smoke Detector, 2-Wire In Stock Other products from System Sensor System Sensor P4W-P Horn Strobe, White, Wall Mount, Four-Wire System Sensor PC2W Horn Strobe, White, Ceiling Mount, Two-Wire, FIRE Lettering System Sensor B210LP Detector Base, Plug-In Heat Sensor (Model 2WT-B and 4WT-B): 135F (57.2C) Freeze Trouble (Model 2WT-B and 4WT-B): 41F (5C) Operating Temperature Range: 2W-B and 4W-B: 32 to 120F (0 to 49C) 2WT-B and 4WT-B: 32 to 100F (0 to 37.8C) Operating Humidity Range: 0 to 95% RH non-condensing Storage Temperature Range: -4 to 158F (-20 to 70C) Diameter (including base): try to correct the interference by one or more of the following measures: All i3 Series detectors are designed to provide open area protection. 3. InnovairFlex duct smoke detectors combine an impressive collection of innovations to greatly simplify HVAC system monitoring. Freeze Trouble (Model 2WT-B and 4WT-B): An overview of latest updates, essential resources, and webinars. Copyright 2023 Honeywell International Inc. from the mounting base without the use of a tool. System Sensor webinars provide relevant and timely information on products, market trends, and legislation. View a list of all System Sensor locations worldwide. ld house alarm system. Page 2 System Sensor two-wire smoke detectors are marked with a compatibility identifier located on the label on the back of the product. Users of this calculator are solely responsible for their own selection and use of products based upon information contained in this calculator and any calculations from this calculator. Add the hardwired 2W-B smoke detector to most existing alarm system control panels. 3825 Ohio Avenue, St. Charles, Illinois 60174 NOTICE: This manual shall be left with the owner/user of this equipment. System Voltage Nominal: hbbd```b``6@$&"%H Compatible with SENS-RDR sensitivity tester; Full agency compliance with UL 268 and UL 2075; Technical Specifications: System Voltage: 12/24 VDC; Access all of System Sensor's tools and software offerings. note describing the malfunction and suspected cause of failure. System Sensor 2WTA-B specifications Below you will find the product specifications and the manual specifications of the System Sensor 2WTA-B. See how you can simplify specification, configuration, and installation of your notification project - saving time and money in the process. Reset all the detectors at the alarm control unit. Please send an email to [email protected] referring to this inquiry to better assist you with your 20P. 0.3 sec 3. At a minimum, cleaning, Models 2W-B and 2WT-B are 2-wire photoelectric smoke detec-, tors; models 4W-B and 4WT-B are 4-wire photoelectric smoke, detectors. diagrams. System Sensor does not provide any design or engineering services. $156.00. may also have other rights which vary from state to state. Operating Voltage: 12/24 V non-polarized nominal, 8.5 min. Once the mounting base is installed, the 2W-B smoke detector attaches to the base by simply inserting the head and turning it clockwise until it locks in place. Ensure proper wiring and power is applied. Disable the zone Standby Current: Figure 3b: Wiring Diagram, 4W-B and 4WT-B To a 4-inch square box with a plaster ring, or manual are available from System Sensor at no charge. and it should be cleaned as outlined in the Maintenance section. 1050 0 obj <>stream Authorization number, send defective units postage prepaid to: System Sensor, Repair In no case shall the Company be liable for any consequential or incidental damages for Operating Temperature Range: HOTFire is a free online site that helps users quickly plan and model notification appliance circuits (NACs) using the entire line of SpectrAlert Advance and L-Series. I have a Vista 6150 15P Control Panel and an old System Sensor 2312/24TB 4 wire Smoke/heat detector. If the detector is in need of maintenance, because its sensitivity has shifted outside the listed limits, the red, LED blinks once every five seconds. at the control panel or module. Honeywell's Esser brings Optical smoke detectors ES Detect which have ability . Models 2WT-B and 4WT-B also feature a restorable, built-in, fixed temperature Direct mount or to ceiling using drywall fasteners (Figure 2). Are a Smoke Alarm and a Smoke Detector The Same Thing? Thank you for the response @disqus_YuNiL6S1Rn:disqus. Peak Standby Current: To view our listings, please visit one of the following sites. Should it become necessary, the screen/sensing chamber is field replaceable. item 2 System Sensor 2W-B I3 Series 2-Wire Photoelectric Smoke Detector, item 3 NEW System Sensor 2W-B 2WB i3 Series 2-Wire Photoelectric Smoke Detector Fire, item 4 System Sensor 2W-B i3 Series 2-wire, Photoelectric Smoke Detector, item 5 NEW System Sensor 2W-B 2WB i3 Series 2-Wire Photoelectric Smoke Detector Fire. Fill out the form and we'll contact you shortly. It sounds like a short problem somewhere in the smoke lines to me, but I am not sure. To engage the tamper-resistant feature, cut the small plastic tab located on the mounting base (Figure 2), and then install the detector. The 2W-B smoke detector works with most Honeywell alarm control panels including the VISTA-20P and VISTA-21iP as System Sensor is a subsidiary of Honeywell. The i3 Series 2W-B uses drift compensation technology and smoothing algorithms which prevent the smoke detector from becoming too sensitive as dust accumulates. The mounting base installation is further simplified by the incorporation of features compatible with drywall fasteners. Alarm Reset Time: The LED indication must not be used in lieu of the tests specified under Testing. Fill out our feedback form! from the end of the feed wire, inserting it into the proper base terminal, and detector to be easily installed or removed. Start-up Time: 1. All System Sensor i3 Series smoke detectors are designed for easy installation, advanced detection and fast inspection. This item: System Sensor 2W-B i3 Series 2-wire, Photoelectric i3 Smoke Detector $52.42 UHPPOTE Wired Sound and Light Fire Alarm Warning Strobe Siren Horn Sound Alert Safety System $18.40 Fire Lite Alarms Dual Action Pull Station w Key Lock $57.06 Honeywell VISTA-20P Ademco Control Panel, PCB in Aluminum Enclosure 399 12 offers from $73.62 Initial LEDStatus Indication Consult NFPA 72, the local Authority Having Jurisdiction (AHJ), and/or applicable codes for specific information regarding the spacing and placement of smoke detectors. The 2W -MOD2 can. down firmly until the screen/sensing chamber is fully seated. 50 6. These limits are designed to provide Have feedback about a particular System Sensor product? No agent, representative, dealer, or employee of the Company has the authority to The conductors used to connect smoke system sensor.com is the site link for a current list of all UL listed compatible smoke detectors. I will say that it came packaged correctly and it functions as designed, would buy again. Hold the heat source about 12 inches from the detector to avoid damage Physical Specifications System connected smoke detectors may be successfully deployed for many years, and no scheduled end of life replacement is prescribed. Should the alarm verification reset exceed 10 seconds, use the maximum initial start-up time. Green LED indicator on the base. 32 Degrees to 120 Degrees F. Battery Backup. Alarm Type. System Sensor makes no representations whatsoever with regard to the quality or function of AFMGs EASE Evac software. Photoelectric smoke detectors work with an alarm system, and when properly maintained and tested, can last for an indefinite period and do not automatically require replacement after a certain period of time like smoke alarms and CO detectors do. for use with i3 Series compatible control panels or the i3 Series 2W-MOD module only. Two LEDs on the detector provide a local visual indication of the detectors status: After an initial power-up delay, the red and green LEDs will blink synchronously once every ten seconds. Therefore, the only Department, RA #__________, 3825 Ohio Avenue, St. Charles, IL 60174. Near fresh air inlets or returns or excessively drafty areas. item 6 System Sensor 2W-B i3 Series 2-wire, Photoelectric Smoke Detector. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Refer to Power must be removed from the detector Some parts of this page is temporarily unavailable. %%EOF System Sensor shall have no liability. 2W-B Datasheet (HTML) - Systemsensor advanced ideas. the 2W-MOD2 installation manual, document D500-4600, for Style D wiring The Companys obligation 4. All models incorporate a state-of-the-art optical sensing chamber and an advanced microprocessor. Smoke Detectors with Sounder and Relay Option System Sensor offers world-class fire detection and notification solutions System Sensor Founded in 1984, System Sensor is a global manufacturer of fire and life safety devices, specializing in smoke detection, carbon monoxide detection, and notification technology for world-wide applications. Press Storage Temperature Range: Fill out the form and we'll contact you shortly. Consult the dealer or an experienced radio/TV technician for help. The 2W-MOD can indicate a need for cleaning, replacement, or a freeze condition (2WT-B only) at the control panel or module. I recommend powering down the system and placing your system on test mode if monitored before swapping in the new smoke. IMPORTANT: This detector must be tested and maintained regularly following NFPA 72 requirements. Power-up However, the i3 Series smoke detector allows for fast and easy inspection. I have a DSC alarm system that my current System Sensors are connected to and would I need to do anything special when I replace the old with the new other then reset the system? List Price $134.00 Our Price $88.99 You Save $45.01 (34%) 3825 Ohio Avenue 41F (5C) The heads and bases are clearly identified as either 2-wire or 4-wire. C. Direct Heat Method (models 2WT-B and 4WT-B only) System Sensors intelligent and conventional modules are designed to help you meet a wide range of application requirements. exclusion or limitation of incidental or consequential damages, so the above limitation 4.3 (21) $6371. System Sensors AV notification devices are the most versatile, easy to install, and cohesive line of audible visual (AV) notification appliances in the industry. Maximum Initial A copy of this list is available from System Sensor upon request. 2009 System Sensor. Alarm Verification* electrical wiring. Start-up Time: photoelectric smoke detector (4 pages), Intrinsically-safe plug-in intelligent photoelectronic smoke detector (6 pages), Single-ended reflected type projected beam smoke detector (19 pages), Single-ended reflected type projected beam smoke detector (14 pages), Air duct smoke detector with extended air speed range (8 pages), Photoelectronic smoke detector with fixed heat and integral temp-3 sounder (4 pages), Reflected type projected beam smoke detector (6 pages), Combination carbon 20 mA 12 Volt Systems (See Figure 6.) The i3 Series detectors include a tamper-resistant feature that prevents removal ey+L) l\q8e)2FWfQCCvBm Yrsza G( Vc Gz;?TP!k5UY6m}*i*OGWfMPMN O_\mV=}gj{sf! tLC>[PWGq9 p applicable state and local codes, and any special requirements of the local Now it's easy to identify System Sensor bases that are compatible with individiual OEM detectors. The i3 line redefines installation ease with its plug-in design. Access all of System Sensor's tools and software offerings. AUX OR + "), INSTALLATION AND MAINTENANCE INSTRUCTIONS, 3825 Ohio Avenue, St. Charles, Illinois 60174. Buy the System Sensor 2WT-B here. 4-Wire Smoke Detector with 135F Fixed Heat Sensor, 2-Wire Smoke Detector with Fixed Heat Sensor, System Sensor 2W-B, 2WT-B, 4W-B & 4WT-B - Installation Guide. 12/24 Volts Non-polarized item 8 System Sensor 2W-B i3 Series 2-wire, Photoelectric Smoke Detector, 5.0 out of 5 stars based on 9 product ratings. identifier located on the label on the back of the product. No. Wire connections are made by stripping approximately 14-inch of insulation from the end of the feed wire, inserting it into the proper base terminal, and tightening the screw to secure the wire in place. Improper connections can After some recent electrical work (new AC unit in the attic) the vista 20p shows fire trouble, and occasionally sets off the alarm. Insert a small screwdriver or allen wrench (0.18 max.) 2. PipeIQ guides users through the initial pipe layout and system configuration for a FAAST aspiration system. The microprocessor allows the detector to automatically adjust its sensitivity back to the factory setting when it becomes more sensitive due to contaminants settling in its chamber. The 2W-B is a 2-wire, photoelectric i3 smoke detector. With. Please read thoroughly System Sensor manual A05-1003, Applications Guide Travis, with 4-wire smokes, you usually don't have to verify compatibility. D100-96-00. Models 2W-B and 2WT-B also include an output that allows an optional Model RA400Z Remote Annunciator to be connected. OVAL AREA OR AT THE 4 to 158F (20 to 70C) unit. When the detector is in the alarm mode, the red LED latches on. Hello, I have a vista 20P (came with the house I bought) that has (4) 2 wire smokes wired in. Ensure proper wiring and power is applied. 7. Loop Verification (models 2W-B and 2WT-B only) Compatible Brand. All models incorporate a state-of-the-art optical sensing, chamber and an advanced microprocessor. (See Figure 4.). To measure the sensitivity of any i3 detector, the SENS-RDR displays the reading, in terms of percent-per-foot obscuration, within seconds. Its simple, step-by-step process makes it easy for users to configure panels and circuits from a variety of devices. The System Sensor 2W-B Photoelectric i3 Smoke Detector, 2-Wire, System Sensor P4W-P Horn Strobe, White, Wall Mount, Four-Wire, System Sensor PC2W Horn Strobe, White, Ceiling Mount, Two-Wire, FIRE Lettering, System Sensor B210LP Detector Base, Plug-In, System Sensor 2151 Photoelectronic Low-Profile Plug-In Detector for Special Applications, System Sensor SCWL Strobe, Ceiling Mount, FIRE, White, Clear Lens, System Sensor EOLR-1 End-of-Line Epoxy Encapsulated Relay, SPST, Plug-in detector line, mounting base included, Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling, Drift compensation and smoothing algorithms. PipeIQ is the free all-in-one system design, configuration, and monitoring software for the System Sensor FAAST line of aspirating smoke detectors, including the new FAAST XT. 32 to 100F (0 to 37.8C) Two-wire models must be used with compatible UL Listed panels only. Please read thoroughly System Sensor manual A05-1003. In wet or excessively humid areas, or next to bathrooms with showers. Notify the proper authorities when the system is back in service. Blink 10 sec When using the System Sensor 2W-B two wire smoke detector with a VISTA-20P or VISTA-21iP alarm control panel, you should wire the smoke detector to zone one. 23 mA 24 Volt Systems Smoke detectors are not to be used with detector guards unless the combination has been evaluated and found suitable for that purpose. If a detector fails any of the above test methods, its wiring should be checked 15 sec The microprocessor allows the detector to automatically adjust its Weight: The System Sensor 2W-B smoke detector has a sensing chamber that that will become dirty with dust over time. it become necessary, the screen/sensing chamber is field replaceable. It can connect with a Honeywell VISTA System at Zone 1. Connectivity. 2. This is because fire alarm control panels vary by When the detector is in the alarm mode, the red LED latches on. The i3 family is founded on three principles: installation ease, intelligence, and instant inspection. However zones 1 and 2 can support 16 on each zone. Detectors must be tested after installation and following maintenance. A copy of this System Sensor web site at www.systemsensor.com. The drop-in ceiling tile speakers, strobes and speaker strobes offer a complete turn-key solution that offers a cleaner and faster installation, reduced labor costs and lower risk than traditional AV notification appliances. Green LED. FireAlarm.com is always at the forefront of the fire & life safety industry offering the most diverse selection of technologies, offerings, and services - all for you to take advantage of FireAlarm.com is able to offer everything from Fire Alarm System Installation and Security Camera Surveillance, all the way to 24/7/365 Central Station Monitoring and Cellular Signal Transmission . Models: 2W-B, 2WT-B, 4W-B, 4WT-B. LED should light within five seconds. System Sensor makes no other express warranty for this smoke detecbe obligated to repair or replace units which are found to be defective because of damage, Upload manuals that we do not have and get. This will get the device to stop sounding. Enter a zip code, select a range, and choose a Distributor type to locate the nearest Distributor. 50 A average Models 2W-B and 2WT-B also include an output that allows an optional Model System Sensor's product 2-wire compatibility listings are available onlinefor you to view and print out. All i3 Series detectors are designed to provide open area protection. Hayden here again from Alarm System Store. A05-0395-007 4/09 #2132 SpectrAlert Advance Dimensions Model Description Wall Horn Strobes P2R* 2-Wire Horn Strobe, Standard cd, Red Smoke detectors are not to be used with detector guards unless the combination has been evaluated and found suitable for that purpose. When the sensing chamber gets too dirty and the 2W-B is no longer calibrated to the proper sensitivity, the smoke detector will alert you with a red LED that blinks every five seconds so that you can perform the necessary maintenance. The System Sensor 2WT-B is a 2-wire smoke and heat detector. System Sensor 2W-B Product Description: The System Sensor 2W-B is a i3-Series conventional, two-wire, photoelectric smoke detector.